Table 5-96 Basic information about the PAC600S56-EB
Item
Details
Description
600 W PoE AC&240 V DC Power Module (66mm Width Case, Back to Front, Power panel side exhaust)
Part Number
02314APV
Model
PAC600S56-EB
Appearance
Figure 5-50 Appearance of the PAC600S56-EB
Figures in the document are for reference only, and the actual appearance of the devices may vary depending on the exact device model.
Version Mapping
Table 5-97 Mappings between PAC600S56-EB and product models
Product
Product Model
First Supported Version
Limitations
S5735R-S-V2
S5735R-S48P4X-V2 (98012705)
V600R024C10
-
S5735R-S-V2
S5735R-S24P4X-V2 (98012704)
V600R024C10
-
S5731-S
S5731-S8UM16UN2Q (02354VCD)
V200R022C00
-
S5731-S
S5731-S24UN4X2Q (02354VCC)
V200R022C00
-
Panel
Figure 5-51 Panel of the PAC600S56-EB
1. Running status indicator
2. Air vent hole
3. Airflow flag (air out)
4. Handle
5. Power socket
6. Lock
-
-
Table 5-98 Indicators on the PAC600S56-EB
Silkscreen
Name
Color
Status
Description
-
Running status indicator
Green
Steady on
The power module output is normal.
Green
Fast blinking (4 Hz)
Online loading
-
Steady off
The power module is powered on but not inserted into the system.
The power module input is normal but there is no output due to power overtemperature protection, output overcurrent, output overvoltage protection, short circuit protection, or component failure.
The input is abnormal or there is no output due to no input.
Functions and Features
Table 5-99 Functions and features of the PAC600S56-EB
Functions and Features
Description
Input overvoltage protection
In this protection state, the power module is turned off and stops supplying power. When the fault is eliminated, the power module can automatically resume power supply.
Input undervoltage protection
In this protection state, the power module is turned off and stops supplying power. When the fault is eliminated, the power module can automatically resume power supply.
Output overvoltage protection
In this protection state, the power module is in hiccup protection mode. If the power module enters this mode multiple times, the power output will be locked and the power module cannot automatically resume power supply.
Output overcurrent protection
In this protection state, the power module is in hiccup protection mode. If the power module enters this mode multiple times, the power output will be locked.
You can use any of the following methods to unlock the power module:
Power off the power module for 2s.
Clear the 0x03 alarm.
Run the reset command.
Output short-circuit protection
In this protection state, the power module is in hiccup protection mode. If the power module enters this mode multiple times, the power output will be locked.
You can use any of the following methods to unlock the power module:
Power off the power module for 2s.
Clear the 0x03 alarm.
Run the reset command.
Overtemperature protection
When the temperature of the power module exceeds a specified threshold, the power module stops supplying power. When the temperature falls into the normal range, the power module automatically resumes power supply.
Technical Specifications
Table 5-100 Technical specifications of the PAC600S56-EB
Item
Specification
Dimensions without packaging (H x W x D) [mm(in.)]
40 mm x 66 mm x 215 mm (1.57 in. x 2.6 in. x 8.46 in.)