S5720S-52P-SI-AC Huawei 52-port Switch

Products > Network Switch > S5720S-52P-SI-AC Huawei 52-port Switch

S5720S-52P-SI-AC Huawei 52-port Switch

S5720S-52P-SI-AC Huawei 52-port Switch
new retail
3 year
in stock

Version Mapping

Table 4-598 lists the mapping between the S5720S-52P-SI-AC chassis and software versions.

Table 4-598 Version mapping

Series

Model

Software Version

S5720S-SI

S5720S-P-SI

S5720S-52P-SI-AC

V200R008C00 to V200R019C10 versions

Appearance and Structure

Figure 4-232  S5720S-52P-SI-AC appearance

1

Forty-eight 10/100/1000BASE-T ports

2

Four 1000BASE-X ports

Applicable modules and cables:NOTE: 

If a port uses a GPON optical module, other 1000BASE-X optical ports cannot be used.

3

One ETH management port

4

One console port

NOTE: 

It is used with a console cable. The console cable is not delivered with the switch and needs to be separately purchased if needed.

5

One USB port

6

Ground screw

NOTE: It is used with a ground cable.

7

RPS socket

NOTE: 

It is used with an RPS cable, which is not hot swappable.

8

Jack for AC power cable locking strap

NOTE: The AC power cable locking strap is not delivered with the switch.

9

AC socket

NOTE: 

It is used with an AC power cable.

-

-

Port Description

10/100/1000BASE-T port

A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s, and must use an Ethernet cableTable 4-599 describes the attributes of a 10/100/1000BASE-T Ethernet electrical port.Table 4-599 Attributes of a 10/100/1000BASE-T Ethernet electrical port

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3, IEEE802.3u, IEEE802.3ab

Working mode

10/100/1000 Mbit/s auto-sensing

Maximum transmission distance

100 m

1000BASE-X port

When a 1000BASE-X port uses a GE optical module, it can only transmit and receive data at 1000 Mbit/s and does not support the 100 Mbit/s transmission speed. When a 1000BASE-X port uses a GE copper module, it can transmit and receive data at 10 Mbit/s, 100 Mbit/s, or 1000 Mbit/s. When a 1000BASE-X port uses a 10GE optical module, SFP+ high-speed copper cable, or active optical cable (AOC), the port can only be used for stack connection. Table 4-600 describes the attributes of a 1000BASE-X port.Table 4-600 Attributes of a 1000BASE-X port

Attribute

Description

Connector type

LC/PC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3z

Console port

The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4-601.Table 4-601 Attributes of a console port

Attribute

Description

Connector type

RJ45

Standards compliance

RS-232

Working mode

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s

Default value: 9600 bit/s

ETH management port

You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. The port must use an Ethernet cable. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. Table 4-602 describes the attributes of an ETH management port.Table 4-602 Attributes of an ETH management port

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3

Working mode

10/100 Mbit/s auto-sensing

Maximum transmission distance

100 m

In V200R012C00 and later versions, you can log in to the switch that contains the ETH management port for the first time through the ETH port. For details, see "First Login to a Switch" in the Configuration Guide - Basic Configuration. If you have logged in to the device for the first time by pressing and holding the MODE button for 6 seconds or longer and saved the configuration, the default configuration on the ETH port will be cleared. In this case, you cannot log in to the switch for the first time through the ETH port. You are advised to log in to the switch for the first time through the ETH port.

USB port

The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

Indicator Description

The S5720S-52P-SI-AC has the same types of indicators as the S5720S-52X-SI-AC. For details, see Indicator Description.

Power Supply Configuration

The S5720S-52P-SI-AC has a built-in power module and does not support pluggable power modules. It can connect to an RPS1800 power supply for power redundancy.

Figure 4-233 shows the power supply mode of a built-in AC power module. The built-in AC power module (PWR) receives power from an external power source and provides a 12 V output to the chassis.Figure 4-233 Power supply mode of a built-in AC power module

L: live wire

N: neutral wire

PGND: protection ground wire

GND: 12 V reference ground

Heat Dissipation

The S5720S-52P-SI-AC has a built-in fan for forced air cooling. The airflow direction is left-to-right.

This figure only shows the airflow direction and does not depict the actual device.

Technical Specifications

Table 4-603 lists technical specifications of the S5720S-52P-SI-AC.

Table 4-603 Technical specifications

Item

Description

Memory (RAM)

512 MB

Flash

512 MB in total. To view the available flash memory size, run the display versioncommand.

Mean time between failures (MTBF)

90.07 years

Mean time to repair (MTTR)

2 hours

Availability

> 0.99999

Service port surge protection

Common mode: ±6 kV

Power supply surge protection

±6 kV in differential mode, ±6 kV in common mode

Dimensions (H x W x D)

  • Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 224.9 mm (1.72 in. x 17.4 in. x 8.85 in.)

  • Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 237.3 mm (1.72 in. x 17.4 in. x 9.34 in.)

Weight (with packaging)

5 kg (11.02 lb)

Stack ports

GE electrical ports and GE SFP optical ports on the front panel

RTC

Supported

RPS

Supported

PoE

Not supported

Rated voltage range

100 V AC to 240 V AC, 50/60 Hz

Maximum voltage range

90 V AC to 264 V AC, 47 Hz to 63 Hz

Maximum power consumption (100% throughput, full speed of fans)

51.5 W

Typical power consumption (30% of traffic load)
  • Tested according to ATIS standard

  • EEE enabled

  • No PoE power consumption

33 W

Operating temperature

0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)NOTE: 

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Short-term operating temperature

-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)

NOTE: 

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
  • The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.

  • The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.

  • The equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.

The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.

The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.

Storage temperature

-40°C to +70°C (-40°F to +158°F)

Noise under normal temperature (27°C, sound power)

< 50.2 dB(A)

Relative humidity

5% to 95%, noncondensing

Operating altitude

0-5000 m (0-16404 ft.)

Certification

  • EMC certification

  • Safety certification

  • Manufacturing certification

Part number

02350DLQ